This comprehensive ms pipe c class weight chart in kg, mm, pdf enables construction professionals to determine accurate material requirements for structural applications. Our detailed specifications support precise project planning while facilitating efficient procurement through modern b2b portal systems.

Comprehensive MS Pipe C Class Weight Chart in KG and MM Specifications

Complete MS Pipe C Class Weight Chart

Nominal Bore (MM)

Outer Diameter (MM)

Wall Thickness (MM)

Weight per Meter (KG)

Weight per 6M Length (KG)

Internal Diameter (MM)

Cross-sectional Area (cm²)

15 (1/2")

21.3

2.65

1.27

7.62

15.90

1.99

20 (3/4")

26.9

2.87

1.69

10.14

21.16

3.52

25 (1")

33.7

3.38

2.41

14.46

26.94

5.70

32 (1.25")

42.4

3.56

3.24

19.44

35.28

9.78

40 (1.5")

48.3

3.68

3.85

23.10

40.94

13.17

50 (2")

60.3

3.91

5.11

30.66

52.48

21.65

65 (2.5")

76.1

4.05

6.78

40.68

68.00

36.32

80 (3")

88.9

4.05

7.95

47.70

80.80

51.29

100 (4")

114.3

4.50

11.41

68.46

105.30

87.16

125 (5")

139.7

4.85

15.06

90.36

130.00

132.73

150 (6")

168.3

4.85

18.16

108.96

158.60

197.62

200 (8")

219.1

5.40

26.62

159.72

208.30

340.85

250 (10")

273.0

6.35

39.14

234.84

260.30

532.46

300 (12")

323.9

6.35

46.72

280.32

311.20

760.78

MS Pipe C Class Material Specifications

Chemical Composition Standards

Element

Percentage Range

Standard Specification

Quality Grade

Carbon (C)

0.15 - 0.25%

IS 1239 Part 1

C Class Medium

Manganese (Mn)

0.30 - 0.70%

IS 1239 Part 1

Standard Grade

Phosphorus (P)

Max 0.050%

IS 1239 Part 1

Quality Control

Sulfur (S)

Max 0.050%

IS 1239 Part 1

Purity Standard

Silicon (Si)

0.10 - 0.40%

IS 1239 Part 1

Structural Grade

Mechanical Properties

Property

Value Range

Test Method

Application Standard

Tensile Strength

330-370 N/mm²

IS 1608

Structural Applications

Yield Strength

205 N/mm² (Min)

IS 1608

Load Bearing Capacity

Elongation

23% (Min)

IS 1608

Ductility Measurement

Hardness

67 HRB (Max)

IS 1608

Surface Durability

Application-Specific Weight Calculations

Water Supply Systems

Pipe Size

Application Type

Standard Length

Total Weight (KG)

Installation Factor

25mm

Residential Supply

100 meters

241.0

1.15x

50mm

Commercial Supply

100 meters

511.0

1.20x

100mm

Industrial Supply

100 meters

1141.0

1.25x

150mm

Municipal Supply

100 meters

1816.0

1.30x

Structural Framework Applications

Configuration

Pipe Combination

Total Weight per Unit

Load Capacity

Safety Factor

Column Support

150mm + 100mm

29.57 KG/meter

85 kN

2.5

Beam Framework

100mm + 80mm

19.36 KG/meter

62 kN

2.2

Truss Assembly

80mm + 65mm

14.73 KG/meter

45 kN

2.0

Quality Assurance and Testing Standards


Hydrostatic Testing Requirements

MS pipe c class undergoes rigorous pressure testing to ensure structural integrity. Standard test pressures range from 2.5 to 4.0 MPa depending on nominal bore specifications, with testing duration maintained for minimum 10 seconds per IS 1239 standards.


Surface Treatment Specifications

Treatment Type

Application Method

Coverage (g/m²)

Corrosion Resistance

Hot Dip Galvanizing

Immersion Process

610 minimum

15-20 years

Zinc Coating

Electroplating

275 minimum

8-12 years

Primer Coating

Spray Application

125 minimum

5-8 years